Penggunaan Interpolasi Bilinier Pada Akuisisi Data Massa

Authors:

  • Muhammad Ifan Saputra
    Universitas Lampung
  • Sri Ratna Sulistiyanti
    Universitas Lampung
  • F.X. Arinto Setyawan
    Universitas Lampung

Abstract

The bilinear interpolation method is generally used to improve images that have noise. However, in this research the bilinear interpolation method will be used to determine the weight value of a digital scale designed with four load cell sensors. Data collection was carried out by placing loads at nine different points. The loads used are 2kg and 5kg. The results of this research are that the value of the point in the center or on the axis of the four load cells, namely points B, D, E, F, and H, has the same voltage as the actual value, namely for a 2kg weight of 4.31 mV. and for a weight of 5 kg it is 5.87 mV. Meanwhile, the other points, namely points A, C, G and I, have values ​​that deviate from the actual value by 0.36 mV or an error of 36%.

 

Keywords: Bilinear Interpolation, Digital Scales, Load Cell Sensors.

Downloads

Download data is not yet available.

Article Metrics

38 Views
318 Downloads

Full Text PDF

How to Cite

Saputra, M. I. ., Sulistiyanti, S. R., & Setyawan, F. A. (2024). Penggunaan Interpolasi Bilinier Pada Akuisisi Data Massa. Jurnal Teori Dan Aplikasi Fisika, 12(02). https://doi.org/10.23960/jtaf.v12i02.376